Document ID: 44080001 Rev: A Technical Support: 1-800-626-6912 Page 13 of 28
INSTALLATION INFORMATION ELECTRICAL
ELECTRICAL SERVICE
110V: 110V, 60 Hz, 2.75 Amp GFCI protected grounded circuit must be used to supply power to the
pedicure spa.
Grounding Instructions
WARNING – When using electrical products, basic precautions should always be followed, including the
following:
1. DANGER: RISK OF ELECTRIC SHOCK. Connect only to a circuit protected by a ground-fault circuit
interrupter.
2. Grounding is required. The unit should be installed by a qualified service representative and grounded.
This product must be grounded. If it should malfunction or break down, grounding provides a path of least
resistance for electric current to reduce the risk of electric shock. This product is equipped with a cord having
an equipment-grounding conductor and a grounding plug. The plug must be plugged into an appropriate outlet
that is properly installed and grounded in accordance with all local codes and ordinances.
DANGER
Improper connection of the equipment-grounding conductor can result in a risk of electric shock. Check with a
qualified electrician or serviceman if you are in doubt as to whether the product is properly grounded. Do not
modify the plug provided with the product – if it will not fit the outlet; have a proper outlet installed by a qualified
electrician.
This product is for use on a nominal 120-V circuit and has a grounding plug that looks like the plug illustrated in
the sketch below. Make sure that the product is connected to an outlet having the same configuration as the
plug. No adapter should be used with this product